Eagle 240 Informacje Techniczne

Przeglądaj online lub pobierz Informacje Techniczne dla Nie Eagle 240. Eagle 240 System information Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
INSTINST
INSTINST
INST
ALLAALLA
ALLAALLA
ALLA
TION AND OPERATION AND OPERA
TION AND OPERATION AND OPERA
TION AND OPERA
TIONTION
TIONTION
TION
INSTRINSTR
INSTRINSTR
INSTR
UCTIONSUCTIONS
UCTIONSUCTIONS
UCTIONS
Accura 240Accura 240
Accura 240Accura 240
Accura 240
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - Accura 240

INSTINSTINSTINSTINSTALLAALLAALLAALLAALLATION AND OPERATION AND OPERATION AND OPERATION AND OPERATION AND OPERATIONTIONTIONTIONTIONINSTRINSTRINSTRINSTR

Strona 2 - TABLE OF CONTENTS

8Full ChartThis is the default mode used whenthe Accura 240 is first turned on. Thebottom signal scrolls across the screenfrom right to left. Depth sc

Strona 3 - INSTALLATION

9Window GroupsYou can change the displays on theAccura 240 by using the windows fea-ture. This lets you use different displaysfor your own fishing or

Strona 4

10AUTOMATICWhen the Accura 240 is first turned on,the Automatic feature is enabled. Thisis indicated by the word “AUTO” at thetop of the screen. The A

Strona 5

11The sensitivity menu has left and right arrows, plus a horizontal bar graph.The graph gives a visual indication of the sensitivity level. The number

Strona 6 - Sensor Chart

12range menu appears as shown at right.Press the left or right arrow keys todecrease or increase the range. Theavailable ranges are 0-5, 10, 20, 30,40

Strona 7 - (Water, T-2, T-3, and Speed)

13ZOOM - MANUAL MODEThe Z-IN (zoom-in) and Z-OUT (zoom-out) keys enlarge and reduce thesize of the echoes on the screen when the unit is in the manua

Strona 8

14down arrow keys until the GRAYLINEmenu appears. A screen similar to theone at right appears. Press the leftarrow key to decrease the gray level orth

Strona 9 - OPERATION

15FISH IDThe Fish ID feature identifies targets that meet certain conditions as fish.The microcomputer analyses all echoes and eliminates surface clut

Strona 10

16When the Accura 240 is turned on, FishTrack is enabled. To turn theFishTrack feature off, press the menu key, then press the up or down arrowkeys un

Strona 11

17DISPLAY ZOOM BARWhen the unit is in the split-screen zoommode, the zoom bar doesn’t normallyshow on the screen. The zoom bar showsthe section of wat

Strona 12

TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSINTRODUCTION ...

Strona 13

18ALARMSThe Accura 240 has three different types of sonar alarms. The first is theFish Alarm. It sounds when the Fish I.D. feature determines an echo

Strona 14 - NO ZOOM 2X ZOOM

19the right arrow key again and press thedown arrow key once. This changesthe "1" at the end of the number to a"0". The depth now

Strona 15

20alarm on, press the ALARM key, then highlight the "Fish Alarm" label andpress the right arrow key. The unit will revert to the sonar displ

Strona 16

21The ASP feature has two levels - Nor-mal and High. If you have high noiselevels, try using the “High” ASP set-ting. However, if you are having troub

Strona 17

22"Speaker" label, then press the left arrow key to turn it off.System InformationThis screen shows some basic data about the Accura 240. To

Strona 18

23SimulatorThe Accura 240 has a simulator built in that lets you use it as if you are onthe water. All features and functions of the unit are usable.

Strona 19

24so that the Accura 240 will add onefoot to the depth, since the transduceris one foot below the surface. Pressthe right arrow key, then the up ordow

Strona 20

25WINDOWS SUMMARYGROUP "F"GROUP "H"GROUP "D"GROUP "A"GROUP "E"GROUP "G"GROUP "C"

Strona 21

26TROUBLESHOOTINGIf your unit is not working, or if you need technical help, please use thefollowing troubleshooting section before contacting the fac

Strona 22

273. The water may be deeper than the sonar’s ability to find the bottom. Ifthe sonar can’t find the bottom signal while it’s in the automatic mode,th

Strona 23

1INTRODUCTIONThe Accura 240 is the latest member of the Eagle family that combines ahigh performance sonar with a wide, high definition screen. Using

Strona 24

28NOISEA major cause of sonar problems is electrical noise. This usually appearson the sonar’s display as random patterns of dots or lines. In severe

Strona 25

29EAGLE ELECTRONICSFULL ONE-YEAR WARRANTY“We", “our”, or “us” refers to EAGLE ELECTRONICS, a division of LEI, the manufacturer ofthis product. “Y

Strona 26

30Notes:

Strona 27 - WINDOWS SUMMARY

31How to Obtain Service(Canadian Customers Only)We back your investment in quality products with quick, expert service and genuine Eaglereplacement pa

Strona 28 - TROUBLESHOOTING

32LITHO IN U.S.A. 988-0135-36How to Obtain Service (U.S.A. Only)We back your investment in quality products with quick, expert service andgenuine Eagl

Strona 29

2POWER CONNECTIONSThe Accura 240 works from a twelve-volt battery system. For the bestresults, attach the power cable directly to the battery. You can

Strona 30

3REDWIRE3 ampFUSEBLACKWIRE12 VOLTBATTERYTO SPEED/TEMPOR TEMP SENSORS(Not included)POWER CONNECTIONSTo Accura 240SPEED/TEMPERATURE SENSORSThe Accura 24

Strona 31 - EAGLE ELECTRONICS

4Sensor Chart(Note: Do not use these sensors in any other combination.)ST-TBK = 1 speed sensor and 1 temperature displayST-T BK + TS-2BK = 2 temp sens

Strona 32

5Three Temperature Sensors(Water, T-2, and T-3)Three Temperature Sensorsplus Speed(Water, T-2, T-3, and Speed)TS-12 BKTS-3 BKST-TBKTS-2 BKTS-3 BKAccur

Strona 33 - How to Obtain Service

6KEYBOARDThe keyboard has keys arranged in two vertical columns beneath thearrow keys. The menu key near the bottom left corner of the keyboardactivat

Strona 34 - 800-324-1354

7MENUSThe Accura 240 uses menus extensively to guide you through thefunctions and features of the unit. To use the menus, simply press theMENU key. Th

Komentarze do niniejszej Instrukcji

Brak uwag