Eagle III Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Nie Eagle III. Eagle III Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 36
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
TM
Magna IIIMagna III
Magna IIIMagna III
Magna III
andand
andand
and
Magna III PlusMagna III Plus
Magna III PlusMagna III Plus
Magna III Plus
INSTALLATION AND OPERATION
INSTRUCTIONS
Przeglądanie stron 0
1 2 3 4 5 6 ... 35 36

Podsumowanie treści

Strona 1 - INSTRUCTIONS

1TMMagna IIIMagna IIIMagna IIIMagna IIIMagna IIIandandandandandMagna III PlusMagna III PlusMagna III PlusMagna III PlusMagna III PlusINSTALLATION AND

Strona 2

10KEYBOARD BASICSThe unit sounds a tone when youpress any key. This tells you theunit has accepted a command.ON/CLEARUse this key to turn the unit on

Strona 3 - 5.9" 3.4"

11ID feature is on. The depth range displays on the upper left side of thescreen. On the screen at the bottom of the previous page, the range is fro

Strona 4

12menu. In this case, the range is 60 feet. Nowpress the up arrow key to decrease the range,the down arrow key increases the range. Afteryou select

Strona 5

13This means the Magna III is tracking thebottom in a zoom window, always keeping iton the display.Press the up arrow key to decrease thezoom size, pr

Strona 6 - GOOD LOCATION

14SENSITIVITYThe sensitivity menu lets you control the unit’s ability to pick up echoes. Alow sensitivity level excludes much of the bottom informati

Strona 7 - "D" CELL BATTERY

15Grayline ® is adjustable. Since it shows thedifference between strong and weak echoes,changing the level may require a differentsensitivity setting

Strona 8

16The Fish ID feature can’t be used when the Magna III is in the manualmode. If you turn the automatic feature off, the Fish ID feature willautomatic

Strona 9

17DISPLAY MODEThe Magna III has three different screen modes. The Magna III Plus hassix. To change modes, press the MENU key until the “DISP MODE”(D

Strona 10

18DISPLAY MODE - MAGNA III PLUS ONLYCHT 1 (Chart #1)This is the default mode used when the Ma-gna III Plus is first turned on. It has thefollowing fe

Strona 11

19DIG 2 (Digital #2)The digital depth display shows at the top ofthis screen in very large digits. The digitaltemperature, speed, and log shows benea

Strona 12

2Eagle ElectronicsPO Box 669Catoosa, OK 74015TABLE OF CONTENTSINTRODUCTION ...

Strona 13

20ALARMSFISH ALARMThe Fish Alarm sounds a tone when a fishsymbol appears on the screen. To use thefish alarm, press the menu key until the “FISHALARM

Strona 14

21Deep AlarmThe deep alarm adjusts the same as the shallow alarm. Use the “DEEPALARM” menu to adjust the deep alarm. When the bottom signal goesdeep

Strona 15

22decrease it, press the down arrow key. Press the up arrow key to increasethe contrast. The bar graph in the Dark/Light menu box shows a graph ofth

Strona 16

23TRANSDUCER CONE ANGLESThe sound waves from the transducer spread out into the water in acone shaped beam. This looks much like the beam from a flas

Strona 17

24SURVEYING A LAKEThe most successful anglers on any body of water are those who fish itday after day and year after year. Eventually, they learn the

Strona 18

25BOAT'S DIRECTION OF TRAVELACBBCAOne of the best ways to get fish arches is to expand or “zoom” asegment of the water. For example, from 45 to

Strona 19

26Most fish don’t spawn unless the water temperature is within rathernarrow limits. The surface temperature meter built into the Magna Plushelps iden

Strona 20

27IMPORTANT INFORMATION!If your unit is not working, or if you need technical help, please use thefollowing troubleshooting section before contacting

Strona 21

283. The water may be deeper than the sonar’s ability to find the bottom. Ifthe sonar can’t find the bottom signal while it’s in the automatic mode,

Strona 22

294. The boat must be moving at a slow trolling speed to see fish arches. Ifthe boat is motionless, fish stay in the cone, showing on the display as

Strona 23 - 25'

3SPECIFICATIONSDimensions ... 5.9" W x 5.35" H x 3.4" DInput Voltage ... 10 - 15 vDCCurrent Drain .

Strona 24

30in shallow water, or when the boat is at rest. In nearly all cases, the causeof the malfunction will be the location and/or angle of the transducer

Strona 25

31EAGLE ELECTRONICSFULL ONE-YEAR WARRANTY“We", “our”, or “us” refers to EAGLE ELECTRONICS, a division of LEI, the manufacturer ofthis product. “Y

Strona 26 - HYPOLIMNION

32Eagle's UPS Return ServiceEagle Electronics and United Parcel Service (UPS) are proud to offer allof our customers free shipping for all units

Strona 27

33This UPS shipping offer is good only in the continental United States (excludes Alaska and Hawaii).KEEP THIS LABEL!YOU WILL NEED IT IF YOU EVER NEED

Strona 28

34SPEED/TEMPSENSOR(Magna III Plus models Only)TRANSDUCER,BRACKET,ANDHARDWAREFUSE HOLDERFUSEPOWER CABLEDISPLAY UNITGIMBAL BRACKETRUBBER WASHERGIMBAL KN

Strona 29

35How to Obtain Service(Canadian Customers Only)We back your investment in quality products with quick, expert service and genuine Eaglereplacement pa

Strona 30

36LITHO IN U.S.A. 988-0106-89EAGLE ELECTRONICS PO BOX 669 CATOOSA OK 74015Your unit is covered by a full one-year warranty. (See inside for comple

Strona 31 - FULL ONE-YEAR WARRANTY

4INSTALLATION - BracketYou can install the Magna III on the top of a dash or from an overhead withthe supplied bracket. It can also be installed in th

Strona 32

5POWER CONNECTIONSThe Magna III works from a 12 volt DC system only. For the best results,run the power cable directly to the boat’s battery. Keep t

Strona 33 - FACTORY FOR REPAIR

6SPEED/TEMPERATURE SENSOR INSTALLATION -(Magna III Plus Only)Mount the speed/temp sensor on the boat’s transom in a location where theflow of water is

Strona 34 - 1-800-324-1353

7MAGNA III PORTABLE ASSEMBLYINSTALLING THE BATTERIESRelease the latch on the front of the battery case. Open the compartmentand install four "D&

Strona 35 - How to Obtain Service

8WASHERWASHERNUTBOLTTIENYLONCORDHERESCREWPORTABLE TRANSDUCER ASSEMBLYAssemble the transducer and bracket as shown below. Attach thetransducer to the

Strona 36 - 800-324-1354

9Clean the chosen area of the hull before attaching the suction cup. Locatethe transducer on the hull as shown below. Don't allow the bracket t